|
nom
en anglais |
nom
fr (complément) |
|
" |
inch
COMPLEMENT : écran : 17" NOM FR : pouce |
|
\R |
carriage
return NOM FR : retour chariot |
|
100baseFX |
Fast
Ethernet |
|
100baseVG |
100VGAnylan |
|
100baseVG-Anylan |
100
Voice Grade-AnyLAN |
|
100BaseX |
fast
Ethernet |
|
10base |
10 Mbs
IEEE standards |
10base2
10base2 |
Thinwrire Ethernet Cable |
|
10BASEFB |
10 BASE
Fiber Backbone |
|
10baseFB |
10base
fiber backbone NOM FR : .. |
|
10baseFL |
10base
fiber link NOM FR : … |
|
10BASEFL |
10 BASE
Fiber Link |
|
10BASEFP |
10 BASE
Fiber Passive |
|
10baseFP |
10base
fiber passive NOM FR : ..... |
|
10baseT |
T :
twisted-pair, 10 base T, COMPLEMENT : pin 1 : T+ pin 2 : T- pin 3 :
R+ pin 6 : R- NOM FR : 10Mbits/s |
|
2DD |
NOM FR :
double densité (DD) |
|
3D |
three-dimensions NOM FR : 3 dimensions |
|
A/D |
Analog
to Digital NOM FR : analogique vers le digital |
|
A/V |
Audio/Video NOM FR : audio/vidéo |
|
AA |
Auto
Answer NOM FR : réponse automatique |
|
AAT |
Average
Access Time NOM FR : temps moyen d'accès |
|
A-B |
Allen-Bradley NOM FR : marque d'automates (Allen-Bradley) |
|
ABC |
Atanasoff-Berry Computer |
|
ABIOS |
Advanced
Basic Input Output System |
|
ABIOS |
Advanced
BIOS NOM FR : BIOS avancé |
|
AC |
Alternating Current NOM FR : courant alternatif |
|
AC |
Active
Command switch |
|
AC
Frequency |
NOM FR :
fréquence CA (Courant alternatif) |
|
ACIA |
Asynchronous Communication Interface Adapters |
|
ACM |
Address
Complete Message |
|
ACPI |
Advanced
Configuration and Power Interface NOM FR : interface avancée de
configuration et de courant électrique |
|
ACR |
Advanced
Communications Riser NOM FR : … |
|
A-D
converter |
Analogic/Digital converter NOM FR : convertisseur A/N |
|
ADC |
Analog-to-Digital Converter NOM FR : convertisseur
analogique/numérique (CAN) |
|
ADF |
Automatic Document Feeder NOM FR : ..... |
|
ADPCM |
Adaptive
Differential Pulse-Code Modulation NOM FR : ..... |
|
AE |
Applications Engineer |
|
AFC |
AntiFerromagnetically Coupled NOM FR : .. |
|
AFR |
Alternate Frame Rendering |
|
AGA |
Advanced
Graphics Adapter |
|
AGC |
Automatic Gain Control |
|
AGM |
Alternate Graphic Mode |
|
AGP |
Accelerated Graphics Port NOM FR : port graphique accéléré |
|
AHA |
Accelerated Hub Architecture NOM FR : .. |
|
AHRA |
Audio
Home Recording Act |
|
AHT |
Average
Handle Time |
|
AIM |
Advanced
Intelligent Modem NOM FR : .. |
|
AIOD |
Automatic Identified Outward Calling |
|
AIT |
Advanced
Intelligent Tape NOM FR : permet de faire des sauvegardes sur bandes |
|
ALS |
Ambient
Light Sensor NOM FR : capteur d'éclairage ambiant |
|
ALU |
Arithmetic-Logic Unit NOM FR : unité arithmétique et logique |
|
AMI |
American
Megatrends Inc. NOM FR : société de BIOS |
|
AMP |
Active
Monitor Present NOM FR : moniteur actif présent |
|
AMR |
Audio
Modem Riser NOM FR : modem intégré à la carte mère |
|
AMS |
Active-Matrix Screen NOM FR : écran à matrice active |
|
APL |
Advanced
Product Line NOM FR : .. |
|
APM |
Advanced
Power Management NOM FR : gestion avancée d'économie de courant |
|
ARC |
Advanced
RISC Computing |
|
ARCA |
Advanced
RISC Computing Architecture |
|
ARR |
Annualized Return Rate COMPLEMENT : <1% |
|
ARTIC |
A
Real-Time Interface Coprocessor |
|
ASB |
Advanced
System Buffering |
|
ASF |
NOM FR :
introduction feuille à feuille automatique. |
|
ASIC |
Application Specific Integrated Circuit |
|
ASPI |
Advanced
SCSI Programming Interface |
|
AT |
Advanced
Technology NOM FR : technologie avancée |
|
ATA |
AT
Attachment, ATA 100, ATA 133, |
|
ATA |
Advanced
Technology Attachment COMPLEMENT : ATA-100 : 100 M/s ATA-133 : 133
Mo/s NOM FR : technologie évoluée de raccordement |
|
ATAPI |
Advanced
Technology Attachment Peripheral Interface
/ NOM FR :
synonyme d'ATA |
|
ATDM |
Asynchronous Time Division Multiplexing |
|
ATF |
Auto
Tracking Following |
|
ATX |
AT
eXtended, advanced technology Extended NOM FR : norme ATX (boitier,
caisse) |
|
AUI |
Adapter
Unit Interface NOM FR : interface standard IEEE 802.3 en DB-15 |
|
AVR |
Automatic Voltage Regulator NOM FR : régulation automatique de
tension |
|
AWG |
American
Wire Gauge NOM FR : standard américain de mesure de taille de
conducteur électrique |
|
backup
browser |
BBR |
|
BBUL |
Bumpless
Build-Up Layer NOM FR : .. |
|
BCU |
Bus-Control Unit |
|
BE |
Back End |
|
BEDO |
Burst
EDO NOM FR : mémoire BeDO |
|
BEDO
DRAM |
Burst
EDO DRAM |
|
BEDO RAM |
Burst
Extended Data Out RAM |
|
BF |
Bus
Frequency NOM FR : fréquence du bus |
|
BICMOS |
Bipolar
Complementary Metal-Oxide Semiconductor |
|
BIOS |
Basic
Input / Output System NOM FR : système de base (entrée/sortie) |
|
BIOS PNP |
BIOS
Plug aNd Play NOM FR : BIOS Plug & Play |
|
BIU |
Bus
Interface Unit |
|
BLER |
BLock
ERror rate NOM FR : ..... |
|
BMB |
Baseboard Management Bus NOM FR : ..... |
|
BNC |
Bayonet
Nut Connector NOM FR : connecteur à baïonnette |
|
BPB |
BIOS
Parameter Block |
|
BPP |
Bidirectional Parallel Port |
|
BROUTER |
BRidge
ROUTER NOM FR : pont router |
|
BSB |
Back
Side Buses |
|
BT |
Base
Transmit NOM FR : ..... |
|
BTX |
Balanced
Technology eXtended NOM FR : .. |
|
BURN-PROOF |
Buffer
Under-Run error PROOF NOM FR : technologie de sécurité pour la
gravure |
|
Burst
EDO |
BEDO |
|
CANBUS |
Controller Area Network Bus NOM FR : ..... |
|
CAP |
CAPS,
capital letters NOM FR : majuscule (maj.) |
|
CAS |
Column
Address Strobe NOM FR : .. |
|
CAT |
CATegory
(CAT5, CAT6,…) NOM FR : catégorie (cat5, CAT6,...) |
|
CAV |
Constant
Angular Velocity NOM FR : vitesse angulaire constante |
|
CD |
Carriage
Detect COMPLEMENT : 1/9 pour db9 NOM FR : détection de porteuse |
|
CD |
Compact
Disk NOM FR : lecteur de CD-ROM |
|
CD-DA |
Compact
Disc Digital Audio NOM FR : disque audionumérique |
|
CD-extra |
NOM FR :
CD audio (CD-DA) et une partie données informatique. |
|
CDFS |
Compact
Disc Filing System NOM FR : système de fichiers CD-ROM |
|
CD-I |
CDI :
Compact Disc Interactive NOM FR : compact disque interactif |
|
CD-MO |
Compact
Disc Magneto-Optical |
|
CD-R |
Compact
Disc Recordable |
|
CDRAM |
Cache
DRAM |
|
CD-ROM |
Compact
Disc-Read Only Memory, CDROM NOM FR : cédérom |
|
CD-RTOS |
Compact
Disk - Real Time Operating System |
|
CD-RW |
Compact
Disc - Read Write NOM FR : CD réinscriptible |
|
CD-WO |
Compact
Disc - Write Once NOM FR : .. |
|
CE |
Consumer
Electronics |
|
CEA |
Consumer
Electronics Association |
|
CES |
Consumer
Electronics Show |
|
CGA |
Color
Graphic Adapter NOM FR : adaptateur graphique couleur |
|
CHRP |
Common
Hardware Reference Platform |
|
CHS |
Cylinder
Head Sector NOM FR : cylindre tête secteur |
|
CIC |
Carrier
Identification Code |
|
CLKMUL |
CLocK
MULtiplier |
|
CLV |
Constant
Linear Velocity NOM FR : vitesse linéaire constante |
|
CMOS RAM |
Complementary Metal Oxide Semiconductor RAM NOM FR : ..... |
|
CN |
Connected Network NOM FR : réseau connecté |
|
CNR |
Communications and Network Riser |
|
COC |
Chip On
Ceramic NOM FR : ..... |
|
COM |
COMmunication COMPLEMENT : RS232 NOM FR : port série (COM1, COM2) |
|
COM1 |
First
serial Port (asynchronous port) NOM FR : premier port série |
|
COM2 |
Second
serial port NOM FR : port série secondaire |
|
CPI |
Character Per Inch |
|
CPS |
Characters Per Second NOM FR : nombre de caractères par seconde |
|
CPU |
NOM FR :
processeur |
|
CPU |
Central
Processing Unit NOM FR : unité centrale de traitement (UC) |
|
CQ |
Correspondence Quality |
|
CQFP |
Ceramic
Quad Flat Pack NOM FR : ..... |
|
CRIMM |
Continuity RIMM NOM FR : ..... |
|
CROM |
Control
Read Only Memory |
|
CRT |
Cathode
Ray Tube NOM FR : ..... |
|
CRTC |
CRT
Controller, cathode-ray tube controller NOM FR : ..... |
|
CS |
Central
Switch |
|
CSC |
Circuit
Supervision Control NOM FR : .... |
|
CSEL |
Cable
SELect (master/slave jumpers) NOM FR : ..... |
|
CSS |
Contact
Start Stop NOM FR : ..... |
|
CSTN |
Color
Super-Twist Nomadic |
|
CT |
Clock
Time NOM FR : ..... |
|
CTFT |
Color
Thin Film Transistor NOM FR : ..... |
|
CTPA |
Coax-to-Twisted-Pair Adapter |
|
CTRL |
control
NOM FR : touche Contrôle (control) |
|
CTS |
Clear To
Send COMPLEMENT : 5 : broche ou 8/9 broche NOM FR : autorisé à être
envoyé, prêt à envoyer |
|
CYL |
CYLinder |
|
DAC |
Digital
to Analog Converter |
|
DAC |
Data
Acquisition and Control NOM FR : ..... |
|
DACK |
DMA
Acknowledge |
|
DAE |
Digital
Audio Extraction, ripping NOM FR : extraction Audio Numérique |
|
DASP |
Disk
Anti Shock Protection System NOM FR : ..... |
|
Data
Carrier Detect |
DCD NOM
FR : ..... |
|
DB15 |
Ethernet
AUI COMPLEMENT : 15 broches NOM FR : AUI (Ethernet AUI) |
|
DB9 |
rs-232/V.24 NOM FR : connecteur db9 |
|
DBB |
Dynamic
Bass Boost NOM FR : ..... |
|
DC |
Distance
Configuration NOM FR : configuration de distance |
|
DC |
Direct
Current NOM FR : courant continu |
|
DCAM |
Direct
Chip Attach Module |
|
DCC |
Direct
Cable Connection NOM FR : ....... |
|
DCE |
Data
Communication Equipment NOM FR : ..... |
|
DCI |
Display
Control Interface NOM FR : ..... |
|
DD |
Double
Density NOM FR : double densité |
|
DDC |
Display
Data Channel NOM FR : ..... |
|
DDMA |
Distributed DMA NOM FR : ..... |
|
DDR |
Double
Data RAM COMPLEMENT : DDR266, DDR400, NOM FR : .. |
|
DDR-SDRAM |
Double
Data Rate Random Access Memory NOM FR : Mémoire vive à vitesse
d'accès doublée (> SDRAM) |
|
DDS |
Digital
Data Storage NOM FR : ...... |
|
DDWG |
Digital
Display Working Group NOM FR : ..... |
|
DEC423 |
COMPLEMENT : ex : connexion pour une imprimante LA75 Digital NOM FR
: connecteur MMJ (VAX) |
|
DFB |
Distributed FeedBack laser diode NOM FR : ..... |
|
DFP |
Digital
Flat-Panel port |
|
DFT |
Drive
Fitness Ttest |
|
DIB |
Dual
Independent Bus NOM FR : ..... |
|
DIMM |
Dual
In-line Memory Module NOM FR : module de mémoire double en ligne |
|
DIN |
Deutsche
Industrie Norm (German) NOM FR : ..... |
|
DIN-TYPE |
4-pin
mini-Din, 5-pin DIN, 6-pin Mini DIN, NOM FR : type de connecteurs du
types DIN |
|
DIP |
Dual
In-line Pin |
|
DLQ |
Dead
Letter Queue NOM FR : ..... |
|
DLT |
Digital
Linear Tape NOM FR : cartouche DLT pour les sauvegardes |
|
DMA |
Direct
Memory Access COMPLEMENT : channel 3 : ECP (LPT1) NOM FR : accès
directe à la mémoire |
|
DP |
Decentralized Peripherical NOM FR : périphérique décentralisé |
|
DPI |
Dots Per
Inch COMPLEMENT : très bonne impression : 300 DPI NOM FR : points
par pouce (DPI) (PPP) |
|
DQ |
Draft
Quality NOM FR : qualité brouillon |
|
DRAM |
Dynamic
Random Access Memory COMPLEMENT : accès : 60-70 nanosecondes NOM FR
: ..... |
|
DRDRAM |
Direct
Rambus DRAM |
|
driver |
NOM FR :
pilote (imprimante,…) |
|
DSR |
Data Set
Ready COMPLEMENT : 6 : broche NOM FR : prêt à transmettre |
|
DSTN |
Double-layer SuperTwist Nematic LCD NOM FR : ..... |
|
DTC |
Data
Terminal Controller NOM FR : ..... |
|
DTR |
Data
Terminal Ready COMPLEMENT : 4/9 broche NOM FR : terminal de données
prêt |
|
Dual
Processor |
DP NOM
FR : ..... |
|
DVD |
Digital
Video Disc NOM FR : ..... |
|
DVD |
Digital
Versatile Disc COMPLEMENT : simple couche : 4,7 M, double couche :
8,5 M NOM FR : disque vidéo numérique (rés. : 720x576) |
|
DVD-E |
Digital
Video Disc-Erasable |
|
DVD-R |
Digital
Video Disk-Recordable NOM FR : ..... |
|
DVD-ROM |
Digital
Versatile Disc-ROM |
|
DVI |
Digital
Video Interface COMPLEMENT : 25 broches + 5 C1 à C5 NOM FR :
connecteur DVI pour écran LCD |
|
DVM |
Digital
Volt Meter |
|
EAN |
Electronic Article Numbering NOM FR : ..... |
|
ECC |
Error
Check and Correcting NOM FR : type de mémoire RAM autocorrective. |
|
ECHS |
Enhanced
Cylinder Heads Sectors |
|
ECP |
Enhanced
Capabilities Port NOM FR : port (eCP) |
|
ED/Q |
Extended-Distance/Quiet |
|
EDD |
Enhanced
Disk Drive NOM FR : ..... |
|
EDGE |
Enhanced
Data Rates for GSM Evolution |
|
EDI |
Electronic Data Interchange NOM FR : échange de Données
Informatiques |
|
EDO |
Extended
Data Out COMPLEMENT : 60 ns, NOM FR : mémoire Edo |
|
EDO RAM |
Extended
Data Out RAM NOM FR : ..... |
|
EDPT |
Enhanced
Disk Parameter Table NOM FR : ..... |
|
EDS |
Electronic Data Systems |
|
EEPROM |
Electrically Erasable Programmable ROM NOM FR : mémoire morte
effaçable électriquement |
|
EFF |
Electronic Frontier Foundation |
|
EFI |
Electromagnetic Field Interference NOM FR : .. |
|
EFM |
Eight to
Fourteen Modulation data encoding NOM FR : huit à quatorze
modulations |
|
EGA |
Enhanced
Graphics Adapter COMPLEMENT : carte EGA NOM FR : adaptateur
graphique amélioré |
|
EHF |
Extremely High Frequency NOM FR : extrêmement haute fréquence
(hardware) |
|
EIA |
Electronic Industries Association |
|
EIA |
Electronic Industries Alliance NOM FR : association américaine de
fabrications d'électronique |
|
EIDE |
Enhanced
IDE |
|
E-IDE |
Enhanced
Integrated Drive Electronic NOM FR : ..... |
|
EISA |
Enhanced
Industry Standard Architecture NOM FR : bus Eisa |
|
EIST |
Enhanced
Intel SpeedStep Technology |
|
ELQ |
Enhanced
Letter Quality |
|
EM |
ElectroMagnetic NOM FR : .. |
|
EMC |
ElectroMagnetic Compatibility NOM FR : compatibilité
électromagnétique |
|
EMI |
Electromagnetic Interference NOM FR : interférence électromagnétique |
|
EMM |
Expanded
Memory Manager |
|
EMP |
Electromagnetic Pulse NOM FR : ..... |
|
EMS |
Expanded
Memory Specification NOM FR : spécification de mémoire étendue |
|
ENIAC |
Electronic Numerical Integrator And Calculator |
|
EO |
End
Office NOM FR : .... |
|
EPP |
Enhanced
Parallel Port NOM FR : port parallèle amélioré |
|
EPROM |
Erasable
Programmable Read-Only Memory NOM FR : mémoire morte reprogrammable |
|
ESATA |
External
SATA |
|
ESC |
ESCape
COMPLEMENT : touche echap NOM FR : échapper |
|
ESCON |
Enterprise System Connection NOM FR : ..... |
|
ESD |
ElectroStatic Discharge |
|
ESDI |
Enhanced
Small Devices Interface |
|
ESN |
Electronic Serial Number NOM FR : .... |
|
FA |
Female
Adaptator |
|
FANFOLD |
Fanfold
media NOM FR : en pliage accordéon |
|
FASIC |
Function
and Algorithm-Specific Integrated Circuit NOM FR : ..... |
|
FAST ATA |
FAST AT
Attachment |
|
FAST
SCSI |
SCSI 2
NOM FR : Interface de débit maxi de 10 Mo/s. |
|
FC-PGA |
Flip-Chip Pin Grid Array |
|
FDC |
Floppy
Disk Controller NOM FR : ..... |
|
FDD |
Floppy
Disk Driver NOM FR : contrôleur de disquettes |
|
FDD |
Fixed /
Floppy Disk Drive NOM FR : lecteur de disquette |
|
FDDI |
Fiber
Distributed Data Interface NOM FR : ..... |
|
FDU |
Floating
Point Unit NOM FR : unité de calcul en virgule flottante |
|
FF |
Flip
Flop NOM FR : bascule |
|
FHS |
Fan
Heat-Sink NOM FR : ..... |
|
FIC |
Flex
Interconnect Cable NOM FR : ..... |
|
FIO |
Future
I/O |
|
FM |
Frequency Modulation NOM FR : modulation de fréquence |
|
FO |
Fiber-optic NOM FR : fibre optique |
|
FOIRL |
Fiber
Optic Inter Repeater Link NOM FR : ..... |
|
FOT |
Fiber
Optic Transceiver NOM FR : ..... |
|
FPM |
Fast
Page Mode NOM FR : module de mémoire RAM classique |
|
FPM DRAM |
Fast
Page Mode DRAM NOM FR : ..... |
|
FPU |
NOM FR :
coprocesseur arithmétique |
|
FRAD |
Frame
Relay Access Device NOM FR : .... |
|
FRU |
Field-Replaceable Unit, FRUs, NOM FR : ..... |
|
FSB |
Front
Side Bus NOM FR : BUS à 333 Mhz (FSB 333 Mhz) |
|
FST |
Flat
Square Tube NOM FR : écran plat à coin carré |
|
FTP |
Folded
Twisted Pair NOM FR : paire torsadée écrantée |
|
FTTO |
Fiber-To-The-Office |
|
FULL HD |
FULL
High Definition NOM FR : pleine haute définition (1920x1080 |
|
FWH |
FirmWare
Hub NOM FR : ..... |
|
GAP |
head gap
lever NOM FR : entrefer |
|
GB |
Giga-Byte, GB, COMPLEMENT : 1.048.576 octets, disque dur : 120 Gb
(Go) NOM FR : Go, giga-octet |
|
GB |
GigaBit,
Gb, NOM FR : giga bit (Gb) |
|
GBE |
Gigabit
Ethernet NOM FR : ..... |
|
GBIC |
Gigabit
Interface Converter NOM FR : ..... |
|
GCCD |
Glass-Passivated Ceramic Chip Diode |
|
GDI |
Graphical Device Interface |
|
GDT |
Graphic
Display Terminal NOM FR : terminal graphique |
|
GFLOPS |
Billions
of FLOating Point Operations Per Second NOM FR : ..... |
|
GGSN |
GPRS
Support Node |
|
GHZ |
GigaHertZ COMPLEMENT : 3 GHz (vitesse du processeur : Pentium IV)
NOM FR : gigahertz |
|
GIB |
GIgabinary Bytes NOM FR : ..... |
|
GMCH |
Graphics
Memory Controller Hub NOM FR : ..... |
|
GND |
GrouND
(signal/system) COMPLEMENT : 5/9 (db9) NOM FR : terre |
|
GPA |
Graphics
Performance Accelerator NOM FR : ..... |
|
GPD |
Ground
Potential difference |
|
GPRS |
General
Packet Radio Service |
|
GPS |
Global
Positioning Satellite/System |
|
GPU |
Graphics
Processing Unit NOM FR : ..... |
|
HAL |
Hardware
Abstraction Layer COMPLEMENT : hal.dll NOM FR : couche d'abstraction
matérielle |
|
HCCR |
HardCopy
Cable Replacement |
|
HCL |
Hardware
Compatibility List NOM FR : liste du matériel compatible |
|
HD |
Hard
Disk COMPLEMENT : capacité : 120 G, vitesse : 7200 t/m, T.accès : 10
ms, NOM FR : disque dur (DD) |
|
HD |
High
Definition NOM FR : haute définition (1280x720) |
|
HDC |
Hard
Disk Controller NOM FR : contrôleur de disque dur |
|
HDCP |
High
Definition Content Protection |
|
HDD |
Hard
Disk Driver NOM FR : unité de disque dur, contrôleur de disque dur |
|
HD-DVD |
High
Definition DVD COMPLEMENT : 30G en double couche NOM FR : disque
haute définition : 15 G en simple couche |
|
HDI |
Head-to-Disk Interference NOM FR : ..... |
|
HDL |
Hardware
Description Language NOM FR : ..... |
|
HD-ROM |
High-Density Read-Only Memory NOM FR : ..... |
|
HDX |
Half-Duplex Transmission |
|
HF |
High
Frequency NOM FR : .. |
|
HFC |
Hybrid
Fiber-Coaxial NOM FR : fibre hybride coaxiale |
|
HGA |
Hercules
Graphics Adapter NOM FR : ..... |
|
HGC |
Hercules
Graphics Card
/ NOM FR : ..... |
|
HIPPI |
High
Performance Parallel Interface NOM FR : interface parallèle haute
performance |
|
HLF |
High-Level Formatting NOM FR : ..... |
|
HMA |
High
Memory Area NOM FR : zone de mémoire haute |
|
HMD |
Head-Mounted Display NOM FR : casque virtuel |
|
HOMERF |
Home
Radio Frequency |
|
HPM |
Hyper
Page Mode NOM FR : ..... |
|
HS |
High
Speed NOM FR : .. |
|
HSCSD |
High
Speed Circuit Switched Data NOM FR : ..... |
|
HVAC |
Heating
Ventilation and Air Conditioning |
|
HVD |
High
Voltage Differential NOM FR : différentiel basse tension |
|
I |
Interleave NOM FR : entrelacé |
|
I/O |
Input /
Output NOM FR : entrée/sortie |
|
IA |
Intel
Architecture NOM FR : ..... |
|
IAM |
Initial
Address Message NOM FR : .... |
|
IB |
In-Bound
NOM FR : ..... |
|
IC |
Integrated Circuit NOM FR : circuit intégré |
|
IC
puller |
Integrated Circuit puller NOM FR : extracteur de circuit intégré |
|
ICH |
Integrated Controller Hub NOM FR : ..... |
|
ICP |
Intelligent Call Processing NOM FR : .... |
|
ICR |
Intelligent Character Recognition |
|
IDC |
Integrated disk controller |
|
IDE |
Integrated Drive Electronics COMPLEMENT : contrôleur IDE NOM FR :
bus Ide |
|
IDT |
Integrated Digital Terminal NOM FR : .... |
|
IDT |
Integrated Device Technology, Inc |
|
IEC |
International Electrotechnical Commission NOM FR : commission
Électrotechnique Internationale (CEI) |
|
IED |
ID Error
Detection NOM FR : ..... |
|
IEEE |
Institute of Electrical and Electronic Engineers NOM FR : ..... |
|
IFB |
I/O and
Firmware Bridge NOM FR : ..... |
|
ILD |
Injection Laser Diode NOM FR : ..... |
|
i-link |
EEE1394,
firewire, Sony i-link tm, NOM FR : ..... |
|
IMAPI |
Image
Mastering Application Program Interface COMPLEMENT :
c:\windows\system32\imapi.exe NOM FR : ..... |
|
IMPA |
Intelligent Multi-Port Adapter |
|
INIT |
Initialize printer NOM FR : .. |
|
INS |
INSert
NOM FR : insertion |
|
IOAPIC |
Input
Output Advanced PIC NOM FR : ..... |
|
IPF |
Itanium
Processor Family |
|
IPI |
Intelligent Peripheral Interface NOM FR : ..... |
|
IPS |
In-Plane
Switching NOM FR : ....... |
|
IR |
InfraRed
NOM FR : infrarouge |
|
IRB |
Inter-Repeater-Bus |
|
IRDA |
Infrared
data association |
|
IRQ 7 |
Interrupt Service Request 7 NOM FR : port d'imprimante LPT1
(interruption) |
|
ISA |
Industry
Standard Architecture NOM FR : bus ISA |
|
ISO |
International Standard Organization NOM FR : fichier iso : image
exacte d'un CD |
|
ISO |
International Standards Organization COMPLEMENT : 200 (ISO speed
ratings) NOM FR : organisation internationale de normalisation |
|
ISTP |
Individually Shielded Twisted Pairs NOM FR : ..... |
|
ITP |
In-Target Probe NOM FR : ..... |
|
JBOD |
Just a
Bunch Of Drivers, JBOD raid NOM FR : spanning des données |
|
KBD |
Keyboard
NOM FR : ..... |
|
KVA |
Kilovolt-Amps NOM FR : ..... |
|
KVAR |
KiloVolt-Amperes-Reactive NOM FR : ..... |
|
KVM |
Keyboard
Video Mouse |
|
L1 |
Level 1
NOM FR : ..... |
|
L2 |
Level 2
NOM FR : une mémoire cache de niveau 2 |
|
LATA |
Local
Access & Transport Area NOM FR : .... |
|
LBA |
Logical
Block Address |
|
LED |
Light
Emitting Diode COMPLEMENT : diode électroluminescente NOM FR :
ampoule ou source lumineuse |
|
LF |
Low
Frequency |
|
LG |
LG
electronics NOM FR : ..... |
|
LIF |
Low
Insertion Force NOM FR : socle LIF |
|
li-Ion |
Lithium-Ion, lithium-Ion polymer NOM FR : ..... |
|
LIT |
NOM FR :
extension de fichier pour Ebook (Microsoft Reader) |
|
LLL |
Link-Loss-Learn |
|
LPI |
Lines
Per Inch NOM FR : lignes par pouce |
|
LPQ |
Line
Printer Queue NOM FR : ..... |
|
LPT |
Line
Printer Port COMPLEMENT : LPT1 NOM FR : nom d'unité logique donné
par DOS aux ports parallèles |
|
LPT1 |
First
Parallel Printer Port NOM FR : ..... |
|
LPT2 |
Second
Parallel Printer Port NOM FR : ..... |
|
LQ |
Letter
Quality NOM FR : qualité courrier |
|
LRU |
Least-Recently Used NOM FR : .. |
|
LSI |
Large
Scale Integration NOM FR : intégration à grande échelle |
|
LSZH |
Low
Smoke Zero Halogen |
|
LTO |
Linear
Tape-Open NOM FR : cartouche LTO pour les backups |
|
LVD |
Low
Voltage Differential NOM FR : différentiel basse tension |
|
M |
M bytes
COMPLEMENT : 500 M NOM FR : méga octets |
|
MA |
COMPLEMENT : 40 mA, NOM FR : milliampère (mA) |
|
MAC |
Medium
Access Control, hardware address NOM FR : méthode d'accès au médium |
|
MB |
MegaBit
NOM FR : méga bit (Mb) |
|
MCA |
Micro
Channel Architecture NOM FR : bus MCA |
|
MCH |
Memory
Controller Hub NOM FR : .. |
|
MCP |
Mode-Conditioning Path Cable |
|
MDA |
Monochrome Display Adapter NOM FR : ..... |
|
MDC |
Mobile
Daughter Card NOM FR : … |
|
MDF |
Main
Distribution Frame NOM FR : .. |
|
MDH |
Module
Date Housing |
|
MFM |
Modified
Frequency Modulated NOM FR : ..... |
|
MHZ |
MegaHertZ COMPLEMENT : 667 MHz (vitesse processeur) NOM FR :
mégahertz |
|
MI |
Mask
Interrupts |
|
MIC |
Media
Interface Connector NOM FR : ..... |
|
MIC |
MICro
NOM FR : microphone |
|
MIDI |
Musical
Instrument Data Interface COMPLEMENT : connecteur DB15 NOM FR :
standard MIDI |
|
MII |
Microsoft/IBM/Intel NOM FR : ..... |
|
MLS |
MultiLayer Switching |
|
MMF |
MultiMode Fiber NOM FR : .. |
|
MMO |
Mobile
Module |
|
MMX |
Multi-Media Extensions NOM FR : ..... |
|
MO |
Magneto-Optical storage |
|
MODEM |
MOdulator / DEModulator NOM FR : modem |
|
MOS |
Metal
Oxide Semiconductor |
|
MOV |
Metal
Oxide Varistors NOM FR : .. |
|
MP |
Multipurpose Cable NOM FR : .. |
|
MPC |
Multimedia Personal Computer NOM FR : ordinateur multimédia |
|
MPO |
multi-path Push-on |
|
MPS |
Multi-Processor System |
|
MPT |
Memory
Protocol Translator NOM FR : ..... |
|
MR |
Microid
Research |
|
Mr |
modem
ready NOM FR : .. |
|
MRI |
Magnetic-Resonance-Imaging |
|
MSA |
Multi-Source Agreement NOM FR : .. |
|
MSAC |
Micro
Sync to Async Converters |
|
MSCDEX |
Microsoft Compact Disc Extensions COMPLEMENT : mscdex.exe NOM FR :
..... |
|
MSDS |
Material
Safety Data Sheets |
|
MSS |
Mass
Storage System NOM FR : ..... |
|
MTBF |
Mean
Time Between Failure NOM FR : temps moyen entre deux pannes |
|
MTTR |
MeanTime
To Repair |
|
MVA |
Matrox
Video card Driver NOM FR : .. |
|
MVA |
Multi-domain Vertical Alignment NOM FR : ..... |
|
N/A |
Not
Available NOM FR : non disponible (option) |
|
N/C |
No-Connect, not connected NOM FR : pas connecté |
|
NAC |
Network
Adapter Card NOM FR : ..... |
|
NAS |
Network
Attached Storage NOM FR : serveur de stockage |
|
NCQ |
Native
Command Queuing |
|
NEC |
National
Electric Code NOM FR : ..... |
|
NEG |
Nippon
Electric Glass |
|
NFU |
Not-Frequently Used NOM FR : ..... |
|
NIC |
Network
Interface Card NOM FR : carte d'interface réseau |
|
NICD |
NIckel
CaDmium NOM FR : ..... |
|
NIST |
National
Institute for Standards and Technology NOM FR : ..... |
|
NLQ |
Near
Letter Quality NOM FR : qualité semi courrier |
|
NMEA |
National
Marine Electronics Association |
|
NMI |
Non-Maskable Interrupt |
|
NOD |
Numerical Optical Disk NOM FR : disque optique numérique |
|
NPM |
network
printer manager NOM FR : ..... |
|
NRTC |
National
Rural Telecommunications Cooperative NOM FR : ..... |
|
NRU |
Not-Recently Used NOM FR : ..... |
|
NTI |
News
Technologies of Information NOM FR : nouvelles technologies de
l'information |
|
OC |
Optical
Carrier NOM FR : ..... |
|
OCR |
Optical
Character Recognition NOM FR : reconnaissance optique de caractères
(ROC) |
|
ODP |
originator dection pattern |
|
ODS |
On
Screen Display NOM FR : .. |
|
OEM |
Original
Equipment Manufacturer COMPLEMENT : constructeur OEM NOM FR :
constructeur d'équipement |
|
OFC |
Optical
Fiber Conductive |
|
OFN |
Optical
Fiber Nonconductive |
|
OH |
off-hook |
|
OLED |
Organic
Light Emitting Diode NOM FR : ..... |
|
OSD |
on-screen display NOM FR : affichage d'écran |
|
OTDR |
Optical
Time Domain Reflectometer NOM FR : ..... |
|
OTG |
On-The-Go |
|
OUI |
Outdoor
Interconnection Units |
|
P |
Progressive NOM FR : progressif |
|
P&D |
Play &
Display |
|
P4 |
COMPLEMENT : P4 2.8 GHz (vitesse processeur) NOM FR : Pentium 4
(processeur) |
|
PA |
Paper
Advance NOM FR : ..... |
|
PAC |
PCI/AGP
Controller |
|
P-ATA |
Parallel
Advanced Technology Attachment |
|
PC |
Personal
Computer NOM FR : ordinateur personnel |
|
PCI |
Peripheral Component Interface NOM FR : bus PCI |
|
PCK |
Parity
ChecK |
|
PCMCIA |
Personal
Computer Memory Card International Association COMPLEMENT : réseau,
compact flash, USB 2, NOM FR : carte pour les pc portables |
|
PDA |
Personal
Digital Assistant NOM FR : assistant personnel |
|
PDU |
Power
Distribution units NOM FR : .. |
|
PE |
paper
empty NOM FR : plus de papier |
|
PENTIUM
D |
Pentium
Dual Core |
|
PET |
Print
Enhancement Technology NOM FR : ..... |
|
PFF |
Page
Fault Frequency NOM FR : ..... |
|
PGDN |
PaGe
DowN |
|
PGUP |
PaGe UP
NOM FR : ..... |
|
PIO |
Programmed Input / Output NOM FR : ..... |
|
PLC |
Programmable Logic Controller NOM FR : automate programmable |
|
PM |
preventive maintenance NOM FR : maintenance préventive |
|
PMA |
power
memory area NOM FR : ..... |
|
PMR |
Private
Mobile Radio NOM FR : ..... |
|
POH |
Power-On
Hours |
|
POR |
Power-On-Reset NOM FR : ..... |
|
POST |
Power-On
Seft Test NOM FR : test automatique à la mise sous tension |
|
PPD |
Parallel
Presence Detect NOM FR : ..... |
|
PPGA |
Plastic
Grid Pin Array NOM FR : ..... |
|
PRD |
print
driver NOM FR : pilote d'impression |
|
PROFIBUS |
PROcess
Field BUS NOM FR : bus (Siemens) |
|
PS |
Printer
Status |
|
PS/2 |
Personal
System / 2, miniDin, COMPLEMENT : 6 pins NOM FR : connecteur pour
souris |
|
PSE |
Power
Sourcing Equipment |
|
PS-POLL |
Power
Save POLL |
|
PTZ |
Pan Tilt
Zoom |
|
QFE |
Quick
Fix Engineering NOM FR : ..... |
|
QIC |
Quarter
Inch Cartridge |
|
RAID10 |
mirrored
drive arrays, raid 0-1 NOM FR : ..... |
|
RAM |
Random
Access Memory COMPLEMENT : MEV NOM FR : mémoire vive |
|
RAMAC |
Random
Access Method of Accounting and Control NOM FR : ..... |
|
RAS |
Row
Address Strobe NOM FR : .. |
|
RCC |
Routing
Control Centre NOM FR : ..... |
|
RCE |
Region
Code Enhancement |
|
RDRAM |
Rambus
DRAM NOM FR : ..... |
|
RDY |
ready
NOM FR : prêt |
|
remote-boot PROM |
remote-boot Programmable Read-Only Memory NOM FR : PROM d'amorçage à
distance |
|
RF |
Radio
Frequency NOM FR : radio fréquence |
|
RI |
Ring
Indicator COMPLEMENT : 9/9 broche NOM FR : indicateur de sonnerie |
|
RIAA |
Recording Industry Association of America NOM FR : ..... |
|
RIMM |
Rambus
Inline Memory Module, direct rambus NOM FR : ..... |
|
RISC |
Reduced
Instruction Set Computer NOM FR : ordinateur à jeu d'instructions
réduit |
|
RJ11 |
registered jack 11, RJ-11, NOM FR : fiche téléphone/modem à 4
contacts |
|
RMB |
Right
Mouse Button NOM FR : ..... |
|
RMW |
Read
Modify Write NOM FR : ..... |
|
RODD |
Rewritable Optic Disk Drive NOM FR : ..... |
|
RPM |
Rotations Per Minute COMPLEMENT : 7200 RPM, NOM FR : tours par
minute (TPM) |
|
RPS |
Redundant Power System NOM FR : ..... |
|
RRIP |
Rock
Ridge Interchange Protocol NOM FR : ..... |
|
RSPL |
Reverse
Spiral Dual Layer NOM FR : ..... |
|
RTC |
Real-Time Clock NOM FR : horloge temps réel |
|
RTS |
Request
To Send COMPLEMENT : 7/9 broche NOM FR : demande pour émettre |
|
RW |
Read-Write NOM FR : ..... |
|
RX |
NOM FR :
réception |
|
RXD |
Receive
Data COMPLEMENT : 2/9 broche NOM FR : réception de données |
|
SAS |
Serial
Attached SCSI COMPLEMENT : SAS : 300 Mo/s, SAS 2 : 600 M/s NOM FR :
.. |
|
SATA |
S-ATA,
Serial Advanced Technology Attachment COMPLEMENT : SATA I : 150M/s
et SATA II : 300M/s NOM FR : communication SATA |
|
SATA II |
Advanced
Serial Technology Attachment II COMPLEMENT : vitesse de transfert :
300 M/s |
|
SCA |
Single
Connector Attachment NOM FR : .. |
|
SCMS |
Serial
Copy Management System NOM FR : ..... |
|
SCS |
Structured Cabling System |
|
SCTP |
Screened
Twisted Pair |
|
SD |
send
data NOM FR : .. |
|
SDR |
Synchronous Dynamic RAM NOM FR : .. |
|
SDRAM |
Synchronous DRAM, Synchronous Dynamic RAM COMPLEMENT : DIMM, NOM FR
: mémoire vive dynamique synchrone |
|
SE |
Systems
Engineer |
|
SE |
Single-ended NOM FR : .. |
|
SEC |
Single
Edge contact |
|
SFT |
System
Fault Tolerance NOM FR : .. |
|
SFTP |
Shielded
and Foilded Twisted Pair NOM FR : ..... |
|
SG |
signal
ground |
|
SHF |
Super
High Frequency |
|
SIC |
Set
Initial Conditions : Command (Lexmark printer) NOM FR : commande
pour les imprimantes Lexmark |
|
SIM |
Subscriber Identification Module NOM FR : .. |
|
SIMM |
Single
Inline Memory Module COMPLEMENT : 32 contacts ou 70 contacts NOM FR
: barrette mémoire SIMM |
|
SIP |
Single
In-line Pin |
|
SIR |
Serial
InfraRed NOM FR : infrarouge série |
|
SIS |
Silicon
Integrated Systems NOM FR : ..... |
|
SMART |
Selt
Monitoring Analysis and Reporting NOM FR : ..... |
|
SMF |
Single-Mode Fiber NOM FR : ..... |
|
SO DIMM |
Small
Outline DIMM |
|
SPGA |
staggered pin grid array NOM FR : ..... |
|
SPI |
SCSI
Parallel Interface NOM FR : ..... |
|
SPP |
Standard
Parallel Port NOM FR : port parallèle standard |
|
SPS |
standby
power supply NOM FR : ....... |
|
SPST |
single-pole single-throw |
|
SPSYNC |
SPindle
SYNCHronization NOM FR : ..... |
|
SPT |
Sectors
Per Track NOM FR : secteurs par piste |
|
SQ |
Signal
Quality detector NOM FR : ..... |
|
SRAM |
Static
Random-Access Memory |
|
SSD |
Solid
State Disk |
|
SSI |
Small-Scale Integration NOM FR : .. |
|
ST |
NOM FR :
connecteur pour fibre optique |
|
STP |
Signaling Transfer Point |
|
SVCD |
Super
Video Compact Disc NOM FR : .. |
|
SVGA |
Super
Video Graphics Array COMPLEMENT : 800x600 NOM FR : résolution SVGA |
|
SXGA |
Super
Extended Graphics Array, 1600 x 1200 COMPLEMENT : 1280x1024 NOM FR :
résolution |
|
TAPI |
Telephony Application Programming Interface |
|
TB |
tera
bytes, TB, COMPLEMENT : 1 TB = 1.204 GB NOM FR : terra octets |
|
TCB |
tail-Circuit Buffers (TCBs) |
|
TCM |
Trellis
Code Modulation NOM FR : ..... |
|
TCP |
Tape
Carrier Package NOM FR : … |
|
TDR |
Time
Domain Reflectometer NOM FR : réflectométrie temporel |
|
TFT |
Thin
Film Transistor |
|
TMDS |
Transition-Minimized Differential Signalling NOM FR : ..... |
|
TNEF |
Transport Neutral Encapsulation Format NOM FR : ..... |
|
TOC |
Table Of
Contents NOM FR : ..... |
|
TPA |
Twisted-Pair A, TPA-, TPA+, |
|
TPB |
Twisted-Pair B, TPB+, TPB- |
|
TPI |
Tracks
Per Inch NOM FR : pistes par pouce |
|
TPO |
ThermoPlastic Ofefin |
|
TPS |
touch
panel systems |
|
TR |
terminal
ready NOM FR : .. |
|
TRANSISTOR |
TRANSformer resISTOR NOM FR : ..... |
|
TTL |
Transistor -Transistor Logic NOM FR : ..... |
|
TX |
Transmission |
|
TXD |
Transmit
Data COMPLEMENT : 3/9 broche NOM FR : transmission de données |
|
UART |
Universal Asynchronous Receiver Transmitter |
|
UDF |
Universal Disk Format NOM FR : ...... |
|
UDMA |
Ultra
Direct Memory Access, ultra-DMA NOM FR : ..... |
|
UHF |
Ultra
High Frequency |
|
UIO |
Universal I/O serial port NOM FR : ..... |
|
UMA |
Upper
Memory Area |
|
UMB |
Upper
Memory Block NOM FR : bloc mémoire supérieur |
|
UMTS |
Universal Mobile Telecommunications Systems NOM FR : ..... |
|
U-NII |
Unlicensed National Information Infrastructure |
|
UPC |
Ultra
Physical Contact NOM FR : .. |
|
UPNP |
Universal Plug and Play NOM FR : ..... |
|
UPS |
Uninterruptible Power Supply |
|
UPS |
Uninterrupted Power Supply NOM FR : alimentation sans interruption
(onduleur) |
|
USART |
Universal Synchrone Asynchrone Receiver Transmitter NOM FR : ..... |
|
UTP |
Unshielded Twisted-Pair |
|
UXGA |
Ultra
Extended Graphics Array NOM FR : résolution (1600x1200) |
|
U-XGA |
Ultra
Extended Graphics Array, 1600 x 1200, |
|
VANC |
Voice
Activated Network Control NOM FR : .... |
|
VBE |
Video
BIOS Extensions NOM FR : ..... |
|
VBR |
Volume
Boot Record |
|
VCD |
Video
Compact Disc NOM FR : ..... |
|
VDT |
Video
Dial Tone, Video Display Terminal NOM FR : tube à rayons cathodiques
(TRC) |
|
VDU |
visual
display unit NOM FR : moniteur vidéo |
|
VESA |
Video
Electronics Standards Association NOM FR : association de fabricants |
|
VF |
Voice
Frequency |
|
VGA |
Video
Graphics Array COMPLEMENT : 15 broches, 640x480, NOM FR : norme VGA
(carte graphique) |
|
VHDCI |
Very
High-Density Connector Interface NOM FR : SCSI-5 |
|
VHF |
Very
High Frequency |
|
VIA |
Virtual
Interface Architecture NOM FR : ..... |
|
VLF |
Very Low
Frequency |
|
VLSI |
Very
Large Scale Integration NOM FR : ..... |
|
VOIC |
Voice
Interface Card NOM FR : ..... |
|
VOM |
Volt-Ohm-Millimeter |
|
VPD |
Virtual
Printer Device NOM FR : ..... |
|
VRAM |
Windows
accelerator card RAM NOM FR : .. |
|
VRAM |
Video
Random Access Memory, video RAM NOM FR : ..... |
|
VRM |
Voltage
Regulator Module NOM FR : .. |
|
VSD |
NOM FR :
variateur de vitesse |
|
WD |
Western
Digital NOM FR : société de disque dur |
|
WPA |
Wi-Fi
Protected Access NOM FR : ..... |
|
WRAM |
Window
Random-Access Memory |
|
WS |
Wait
State NOM FR : état d'attente |
|
WUXGA |
wide
ultra extended graphics array (W-UXGA) COMPLEMENT : 1920 x 1200, |
|
W-XGA |
Wide-Extended Graphics, 1366 x 768, |
|
XGA |
eXtended
Graphics Array COMPLEMENT : 1024x768 NOM FR : ..... |
|
ZIF |
Zero
Insertion Force NOM FR : à force d’insertion nulle |
|
ZSL |
Zero
Slot LAN |